摘要
论述了预应力度在预应力混凝土框架梁抗震概念设计中的易混淆之处,强调了相对受压区高度与预应力度在设计中的主次关系,提出了预应力混凝土框架梁抗震设计的新思路。建议设计时,以相对受压区高度为主要控制指标,并放松预应力度限制。
This paper discusses the misunderstanding of partial prestressing ratio in the seismic conceptual design of the prestressed concrete frame beam.It emphasizes the primary and secondary relationship between the relative height of compression zone and partial prestressing ratio in the design.A new idea of seismic design of the prestressed concrete frame beam is put forward.It is suggested that the relative height of compression zone should be taken as the main control index and partial prestressing ratio should be loosened.
作者
谢靓宇
Xie Liangyu(China Building Technique Group Co.,Ltd.,Beijing 100013,China)
出处
《山西建筑》
2020年第3期46-47,共2页
Shanxi Architecture
基金
中国建筑科学研究院有限公司青年基金项目(20171802331030038)
关键词
预应力混凝土
预应力度
抗震性能
prestressed concrete
partial prestressing ratio
seismic performance