摘要
硫磺尾气分析是硫磺装置重要参数保证,比值分析仪的准确与否直接影响到装置的正常运行,所以本文主要的对比利用比值分析仪现场经常出现的故障,做一个总结,并针对这些故障进行一些改造。
Sulfur tail gas analysis is an important parameter guarantee of sulfur plant. The accuracy of the ratio analyzer directly affects the normal operation of the plant. Therefore,the main focus of this paper is to make a summary of the frequent failures of the ratio analyzer on site,and make some modifications and Implementation for these failures.
作者
刘建云
陈涛
杨菁
Liu Jianyun;Chen Tao;Yang Jing(Instrument Workshop of Inspection and Maintenance Center of PetroChina Karamay Petrochemical Co.,Ltd.,Karamay,Xinjiang,834000)
出处
《石化技术》
CAS
2020年第1期15-16,共2页
Petrochemical Industry Technology
关键词
硫磺
比值分析
故障处理
优化使用
sulfur
ratio analysis
troubleshooting
optimized use