摘要 本文旨在建立原子荧光法测定苹果中总砷和总汞含量不确定度评定的方法。首先通过分析在测定过程中影响不确定度的各个因素,接着对这些因素的不确定度进行评估和量化,最后按数学模型计算出原子荧光法测定苹果中总汞和总砷含量,合成不确定度和扩展不确定度。原子荧光法测定苹果中总汞和总砷含量分别为5.256和189.750μg/kg;相对扩展不确定度分别为14.694%和6.748%;结果表达分别为(5.256±0.772)和(189.750±12.804)μg/kg。不同浓度的待测样品要合理选择标准曲线的对应的浓度点;提高仪器稳定性,增加重复检测样品的次数;合理选择标准溶液的配制方法和移液器非常重要;总砷的测量值比总汞的测量值更接近真值,可信度更高。 To evaluate the uncertainty in determination of total arsenic and total mercury in apple by atomic fluorescence spectrometry.The influence factors of uncertainty in the cource of determination were analyzed and considered.According to mathematical model,the components of uncertainty and the combined uncertainty were calculated.The concentration of total arsenic and total mercury in apple was respectively 5.256 and 189.750μg/kg.The relative expanded uncertainty of total arsenic and total mercury was 14.694%and 6.748%respectively,and the result of the measurement was(5.256±0.772)and(189.750±12.804)μg/kg respectively.The different concentration point of the standard curve should be correctly chosen to evaluate the different concentration of sample;the repeated times of measurement and the stability of the instrument should be increased;the method and pipetting device of configuration standard soution shoule be reasonability chosen.Those factors are very important.The relative expanded uncertainty of total arsenic is smaller than the expanded uncertainty of total mercury.The measured values of total arsenic is closer to the truth than the measured values of total Mercury.
作者 陈利平 张宏雨 刘敏 郝羽 柴静 薛丽 CHEN Li-ping;ZHANG Hong-yu;LIU Min;HAO Yu;CHAI Jing;XUE Li(Supervision and Inspection Center of Agricultural Products Quality of Changping Beijing,Beijing 102200,China)
出处 《食品工业科技》 CAS 北大核心 2020年第1期213-218,共6页 Science and Technology of Food Industry
基金 2019年农产品质量安全监测项目(2019-612301011-000001)
关键词 原子荧光法 总汞 总砷 不确定度 atomic fluorescence spectrometry total mercury total arsenic uncertainty
  • 相关文献

参考文献10

二级参考文献38

  • 1黄涛.ISO/IEC 17025:2005《检测和校准实验室能力的通用要求》中存在的错误[J].电子质量,2006(11):56-58. 被引量:73
  • 2陈天金,魏益民,潘家荣.食品中铅对人体危害的风险评估[J].中国食物与营养,2007,13(2):15-18. 被引量:72
  • 3[1]JJF 1059-1999,测量不确定度评定与表示[S].北京:中国计量出版社,1999.
  • 4NY/T761-2008.蔬菜水果中有机磷、有机氯、拟除虫菊酯和氨基甲酸酯类农药多残留的测定[s].
  • 5JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 6JJG196-1990,常用玻璃量器[S].
  • 7JJG1059-1999.测量不确定度评定与表示[S].[S].,..
  • 8中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..
  • 9GB/T5009.12-2003.食品中铅的测定方法[S].[S].,..
  • 10JJF 1135-2005,化学分析测量不确定度评定[S].

共引文献29

同被引文献167

引证文献19

二级引证文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部