期刊文献+

木梁温度场及受火后力学性能数值模拟 被引量:3

Numerical simulation of temperature field and mechanical properties after fire of timber beams
下载PDF
导出
摘要 运用有限元软件ABAQUS建立四面受火下木梁温度场模型和热-力耦合模型,对截面的温度分布、炭化速率、受火后剩余承载力进行分析并与试验对比。结果表明,木梁的温度场模型能较好地模拟出拐角处呈圆弧状的现象;四面受火下水平方向平均炭化速率为0.87 mm/min,竖直方向平均炭化速率为0.86 mm/min且含水率对炭化深度影响不大;木梁的受火时间对受火后剩余承载力影响较大。 The finite element software ABAQUS was used to establish the temperature field model and the thermo-mechanical coupling model of the four-sided fired timber beams. The temperature distribution, carbonization rate and residual bearing capacity of the fire were analyzed and compared with the test. The results showed that the temperature field model of the timber beam simulates the arc at the corner;the average carbonization rate in the horizontal direction is 0.87 mm/min under four sides, and the average carbonization rate in the vertical direction is 0.86 mm/min;the water content has little effect on the carbonization depth;the fire time of the wooden beam has a great influence on the residual bearing capacity after the fire.
作者 蔡炎 刘永军 李思雨 CAI Yan;LIU Yong-jun;LI Si-yu(School of Civil Engineering,Shenyang Jianzhu University,Liaoning Shenyang 110168,China)
出处 《消防科学与技术》 CAS 北大核心 2020年第1期38-41,共4页 Fire Science and Technology
基金 国家重点研发资助计划项目“村镇建筑灾变机理与适宜性防灾设计理论”(2018YFD1100403)
关键词 木梁 温度场 剩余承载力 有限元分析 timber beams temperature field residual bearing capacity finite element analysis
  • 相关文献

参考文献6

二级参考文献66

  • 1李诫.营造法式图样[M].北京:中国建筑工业出版社,2007.
  • 2CECS252:2009火灾后建筑结构鉴定标准[s].北京:中国计划出版社,2009.
  • 3Canadian wood council. Fire safety in residential bulidings, Build- ing performance series : No. 2.
  • 4Buchanan A. Fire resistance of solid timber structures, Uinvershy of Canterbury, New Zealand ,2005.
  • 5Odeen K. Fire resistance of wood structures, Fire Technology, 1985,21 ( 1 ) :34-40.
  • 6Richardson L. Failure of floor assemblies construced with timber joists, wood trusses or I-joists during fire resistance tests, Proceed- ings of the lOth International Fire Science and Engineering Confer- ence ,2004.
  • 7Noren J. Load-bearing capacity of nailed joints exposed to fire, Fire and materials, 1996,20 : 133-143.
  • 8Richardson L, Batista M. Fire resistance of timber decking for heav- y timber construction, Fire and Materials,2001,25:21-29.
  • 9Beniehou N. Predicting the structural fire performance of solid wood-framed floor assemblies, SIF06-4th International Workshop- Structures in Fire, Aveiro, Portugal ,2006,5:909-920.
  • 10Bullock M, Lennon T, Enjily V. The fire resistance of medium-rise timber frame buildings summary report, Chihern International Fire.

共引文献64

同被引文献19

引证文献3

二级引证文献2