摘要
使用PyroSim软件对某高校高层宿舍楼火灾进行模拟,通过烟气层高度、温度等火场数据的变化得出允许疏散时间ASET。使用MassMotion对宿舍楼内人员疏散进行模拟,得出需要疏散时间RSET,并提出增设疏散出口的改进意见,将模拟数据与经验公式计算的疏散时间相对比,分析导致造成结果差异主要因素。将ASET与RSET进行对比,判断该建筑的火灾危险性,并提出安全疏散措施及相关建议。
PyroSim was used to simulate a high-rise dormitory and the ASET was obtained through the fire field data such as smoke layer height,temperature and so on.MassMotion was used to simulate the evacuation and to obtain the RSET.The suggestion as improving an exit was put forward.The simulation data was compared with the evacuation time calculated by the empirical formula.The main factors which caused the difference in these results were analyzed.ASET was compared with RSET in order to determine the fire hazard of the building.Safety evacuation measures and related recommendations were proposed for the building.
作者
杨海明
赵道亮
孙康娴
刘谦
曾美婷
杨莉
YANG Hai-ming;ZHAO Dao-liang;SUN Kang-xian;LIU Qian;ZENG Mei-ting;YANG Li(College of Urban Construction and Safety Engineering,Shanghai Institute of Technology,Shanghai 201418,China)
出处
《消防科学与技术》
CAS
北大核心
2020年第1期52-55,共4页
Fire Science and Technology
基金
上海市自然科学基金项目(15ZR1440900)
上海应用技术大学中青年教师科技人才发展基金项目(ZQ2018-21)