期刊文献+

Changes in peak inspiratory flow rate and peak airway pressure with endotracheal tube size during chest compression 被引量:1

Changes in peak inspiratory flow rate and peak airway pressure with endotracheal tube size during chest compression
下载PDF
导出
摘要 BACKGROUND:Adequate airway management plays an important role in high-quality cardiopulmonary resuscitation(CPR).Airway management is usually performed using an endotracheal tube(ETT)during CPR.However,no study has assessed the effect of ETT size on the fl ow rate and airway pressure during CPR.METHODS:We measured changes in peak inspiratory fl ow rate(PIFR),peak airway pressure(Ppeak),and mean airway pressure(Pmean)according to changes in ETT size(internal diameter 6.0,7.0,and 8.0 mm)and with or without CPR.A tidal volume of 500 mL was supplied at a rate of 10 times per minute using a mechanical ventilator.Chest compressions were maintained at a constant compression depth and speed using a mechanical chest compression device(LUCAS2,mode:active continuous,chest compression rate:102±2/minute,chest compression depth 2–2.5 inches).RESULTS:The median of several respiratory physiological parameters during CPR was significantly different according to the diameter of each ETT(6.0 vs.8.0 mm):PIFR(32.1 L/min[30.5–35.3]vs.28.9 L/min[27.5–30.8],P<0.001),Ppeak(48.84 cmH2O[27.46–52.11]vs.27.45 cmH2O[22.53–52.57],P<0.001),and Pmean(18.34 cmH2O[14.61–21.66]vs.13.66 cmH2O[8.41–19.24],P<0.001).CONCLUSION:The changes in PIFR,Ppeak,and Pmean were related to the internal diameter of ETT,and these values tended to decrease with an increase in ETT size.Higher airway pressures were measured in the CPR group than in the no CPR group. BACKGROUND: Adequate airway management plays an important role in high-quality cardiopulmonary resuscitation(CPR).Airway management is usually performed using an endotracheal tube(ETT) during CPR.However, no study has assessed the effect of ETT size on the flow rate and airway pressure during CPR.METHODS: We measured changes in peak inspiratory flow rate(PIFR), peak airway pressure(Ppeak), and mean airway pressure(Pmean) according to changes in ETT size(internal diameter 6.0, 7.0, and 8.0 mm) and with or without CPR.A tidal volume of 500 mL was supplied at a rate of 10 times per minute using a mechanical ventilator.Chest compressions were maintained at a constant compression depth and speed using a mechanical chest compression device(LUCAS2, mode: active continuous, chest compression rate: 102±2/minute, chest compression depth 2–2.5 inches).RESULTS: The median of several respiratory physiological parameters during CPR was significantly different according to the diameter of each ETT(6.0 vs.8.0 mm): PIFR(32.1 L/min [30.5–35.3] vs.28.9 L/min [27.5–30.8], P<0.001), Ppeak(48.84 cmH2O [27.46–52.11] vs.27.45 cmH2O [22.53–52.57], P<0.001), and Pmean(18.34 cmH2O [14.61–21.66] vs.13.66 cmH2O [8.41–19.24], P<0.001).CONCLUSION: The changes in PIFR, Ppeak, and Pmean were related to the internal diameter of ETT, and these values tended to decrease with an increase in ETT size.Higher airway pressures were measured in the CPR group than in the no CPR group.
作者 Jung Wan Kim Jin Woong Lee Seung Ryu Jung Soo Park InSool Yoo Yong Chul Cho Hong Joon Ahn Jung Wan Kim;Jin Woong Lee;Seung Ryu;Jung Soo Park;InSool Yoo;Yong Chul Cho;Hong Joon Ahn(Department of Emergency Medicine,Chungnam National University Hospital,Jung-gu,Daejeon,Republic of Korea;Department of Emergency Medicine,College of Medicine,Chungnam National University,Jung-gu,Daejeon,Republic of Korea)
出处 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2020年第2期97-101,共5页 世界急诊医学杂志(英文)
基金 supported by the Chungnam National University Hospital Research Fund,2016
关键词 Cardiopulmonary resuscitation Intratracheal intubation Airway pressure Cardiopulmonary resuscitation Intratracheal intubation Airway pressure
  • 相关文献

参考文献2

二级参考文献3

共引文献8

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部