摘要
分析了酒钢8万m3威金斯转炉煤气柜T型档板偏移、活塞倾斜的现象与成因,提出了详细的调整处理方法,最终达到了设计运行要求。
The phenomenon and causes of T-shaped baffle plate deviation and piston inclination of the 80000 m3 Wiggins converter gasholder in Jiuquan Steel was analyzed and detailed adjustment and treatment method put forward,which has finally achieved the design and operation requirements after implementation.
作者
韩烺钊
李俊雅
HAN Langzhao;LI Junya(The Energy Center of Jiuquan Iron and Steel Group,Jiayuguan,Gansu 735100,China)
出处
《冶金动力》
2020年第2期36-38,共3页
Metallurgical Power
关键词
煤气柜
活塞水平度
调整方法
gasholder
piston levelness
adjustment method