期刊文献+

两种仪器型号的离子色谱仪对饮用水源地下水中溴化物的测定对比研究 被引量:2

Comparative study on determination of Bromide in groundwater of drinking water source by two instruments of Ion Chromatograph
下载PDF
导出
摘要 本文运用瑞士万通883和戴安ICS-1000两种仪器型号的离子色谱仪分别对饮用水源地下水中的溴化物进行测定分析比对,通过对比两种仪器测定方法的线性关系相关系数r(r>0.999)、检出限、精密度、准确度、回收率及相对标准偏差(RSD),其均能达到质量控制要求,且瑞士万通883和戴安ICS-1000在测定饮用水源地下水中溴化物含量方面各具有一定的优势。 In this paper,the ion chromatograph of Swiss Metrohm 883 and Dionex ICS-1000 were used to determine and analyze bromide in the groundwater of drinking water sources respectively.By comparing the linear correlation coefficient r(r>0.999),detection limit,precision,accuracy,recovery and relative standard deviation(RSD)of the two instrument methods,we found that all the parametes can meet the quality control requirements.And Swiss Metrohm 883 and Dionex ICS-1000 each has its own advantages in determining bromide content in the groundwater of drinking water sources.
作者 蒋园园 程海 Jiang Yuanyuan;Cheng Hai(Xuzhou Environmental Monitoring Center Station,Xuzhou 221000,China)
出处 《环保科技》 2020年第1期37-41,共5页 Environmental Protection and Technology
关键词 瑞士万通883 戴安ICS-1000 溴化物 饮用水源地下水 Swiss Metrohm 883 DionexICS-1000 bromide groundwater of drinking source
  • 相关文献

参考文献6

二级参考文献24

共引文献19

同被引文献24

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部