摘要 本文结合工程实际和现场情况,对热泵式溶液调湿新风处理机组,转轮式热回收机组,板翅式显热回收机组和三维热管热回收机组的特点进行了比较。详细分析了在设计城市综合体酒店客房的空调新风时,如何合理选择热回收设备,保证系统运行稳定、可靠,节能效果明显,是设计成功的关键。 This paper combines the actual situation of the project and the field situation,the characteristics of heat pump type fresh air treatment unit for solution humidification,runner type heat recovery unit,plate fin sensible heat recovery unit and three-dimensional heat pipe heat recovery unit are compared.This paper analyzes in detail how to select the heat recovery equipment reasonably when designing the fresh air of the air conditioner in the hotel room of the urban complex,and the key to the success of the design is to ensure the stable and reliable operation of the system and the obvious energy-saving effect.
作者 朱峥彧 ZHU Zheng-yu(Nanjing Jiangbei New Area Construction Engineering Design and Construction Drawing Review Center)
出处 《建筑热能通风空调》 2020年第1期77-79,11,共4页 Building Energy & Environment
关键词 风机盘管加新风空调系统 避难层 热回收机组 fan coil plus fresh air conditioning system refuge floor heat recovery unit