摘要
越来越多的直流输电线路投入运行,电网呈现交直流共存的现象。但直流输电在双极不平衡及单段运行的方式下,对临近的交流变压器造成较大的影响。详细介绍了宾金直流系统对我厂主变造成的影响,以及安装隔直装置后达到的效果。
More and more DC transmission lines are put into operation,and the power grid is coexisting with AC and DC.However,under the mode of bipolar unbalance and single-segment operation of DC transmission,it has a greater impact on the nearby AC transformer.The impact of Binjin DC system on the main transformer of our factory and the effect achieved by installing DC blocking device are introduced in detail.
作者
夏志凌
胡凯波
XIA Zhiling;HU Kaibo(Zhejiang Zheneng Lanxi Power Generation Co.,Ltd.Zhejiang Lanxi 321100,China)
出处
《电工材料》
CAS
2020年第1期24-26,共3页
Electrical Engineering Materials
关键词
主变压器
隔直装置
和应涌流
main transformer
DC blocking device
and inrush current