摘要 国内某钢铁厂焦炉测温用铠装热电偶,安装后使用5天便发生了失效故障,无法显示温度读数。为探究其热电偶失效原因,对其铠装热电偶先后进行了低倍下的宏观形貌观察、扫描断口分析、显微组织分析和电子探针成分分析等。结果表明:该热电偶失效的原因是镍铬端发生了择优氧化。改进措施及建议:使用时合理选择适合型号的热电偶,排除K型热电偶在加工时表面的氧化皮以及还原性介质的介入和采用较小的长径比。 A sheathed thermocouple used in a coke oven in a domestic steel plant became invalid after installed,and used for 5 days,which could not show the temperature readings any more. The failure reasons of the thermocouple were investigated by means of macroscopic appearance observation,fracture analysis by the scanning electron microscope( SEM),microstructure analysis by optical microscope( OM),composition analysis by electro probe microanalyzer( EPMA),respectively. The results show that the failure of the thermocouple is mainly attributed to the preferential oxidation of the nickel-chromium end. Improvement measures and suggestions: select the right type of thermocouple reasonably when using,eliminate the oxide skin on the surface of K-type thermocouple and the intervention of reducing medium during processing,and adopt a smaller length diameter ratio.
作者 蔡欣男 柯娴 喻峰 王金太 Cai Xinnan;Ke Xian;Yu Feng;Wang Jintai(National Engineering Research Center for Instrument Functional Materials,Chongqing Materials Research Institute Co.,Ltd.,Chongqing 400700,China;Chongqing Instrument Functional Materials Testing Institute,Instrument Materials Quality Supervision Test Center of Machinery Industry,Chongqing 400700,China)
出处 《金属热处理》 CAS CSCD 北大核心 2020年第1期61-64,共4页 Heat Treatment of Metals
关键词 焦炉用热电偶 镍铬-镍硅热电偶 择优氧化 绿蚀 thermocouple for coke oven Ni-Cr/Ni-Si thermocouple preferential oxidation green corrosion
  • 相关文献

参考文献3

二级参考文献14

共引文献35

同被引文献33

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部