摘要
采用铜渣与双氧水构成类Fenton体系处理H酸废水,考察了铜渣投加量、双氧水投加量、铜渣粒径和初始pH等因素对处理效果的影响。结果表明,在n(H2O2)∶m(COD)=55 mmol/g、n(H2O2)∶m(铜渣)=10 mmol/g和初始pH=3的条件下,反应180 min,COD及TOC去除率分别为70%和40%,比其他矿物类Fenton体系对H酸废水的处理效果有明显改善。铜渣在酸性条件下是H2O2氧化有机污染物的有效催化剂,有工业应用可能性。
Fenton-like system composed of copper slag and hydrogen peroxide was used to treat H-acid wastewater.The effects of copper slag input,hydrogen peroxide addition,copper slag particle size and initial pH on the treatment effect were investigated. The results show that under the conditions of n(H2 O2)∶m(COD)=55 mmol/g,n(H2 O2)∶m(copper slag)=10 mmol/g and initial pH=3,the removal rates of COD and TOC were 70% and 40% after 180 minutes of reaction. Compared with other mineral Fenton-like systems,the treatment effect of H acid wastewater was significantly improved. Copper slag is an effective catalyst for H2 O2 oxidation of organic pollutants under acidic conditions,and has industrial application possibilities.
作者
张帅
陈泉源
卢钧
杨梦婷
Zhang Shuai;Chen Quanyuan;Lu Jun;Yang Mengting(College of Environmental Science and Engineering,Donghua University,Shanghai 201620,China;Shanghai Institute of Pollution Prevention and Ecological Safety,Shanghai 200092,China;National Environmental Engineering Engineering Textile Industry Pollution Control Engineering Center,Shanghai 201620,China;Shanghai Ship Transportation Science Research Institute,Shanghai 200135,China)
出处
《工业水处理》
CAS
CSCD
北大核心
2020年第3期39-42,共4页
Industrial Water Treatment
基金
国家重点研究发展计划项目(2016YFC0400502)
中央高校基本科研业务费(19D111321)