绝缘盘刚度对轴端接地装置强度的影响

Influence of Insulation Plate Stiffness To The Strength of Axle end Grounding Device
下载PDF
导出
摘要 以某型轴端接地装置为例,分析绝缘盘刚度变化对轴端接地装置强度的影响,并且基于Ansys软件对轴端接地装置中绝缘盘取不同刚度值的情况进行仿真计算,考察轴端接地装置各个部件的应力随绝缘盘刚度值的变化情况,据此确定绝缘盘合适的刚度值,使得轴端接地装置各个部件及螺栓具有合理的材料利用率,以充分发挥各个部件的承载能力。 Taking a certain type of shaft end grounding device as an example,this paper analyzes the influence of rigidity change of insulating disk on bolt connection of shaft end grounding device.Based on ANSYS software,the simulation calculation of different stiffness values of insulating disc in shaft end grounding device is carried out,investigating the variation of stress of each component of the shaft end grounding device with the stiffness of the insulating disk,then proper stiffness value of insulating disc is determined.Reasonable material utilization ratio of each component and bolt of shaft end grounding device is achieved and brought the bearing capacity of each component into full play.
作者 黄学君 HUANG Xuejun(The State Key Laboratory of Heavy Duty AC Drive Electric Locomotive Systems Integration,Zhuzhou 412001 Hunan,China;CRRC Zhuzhou Electric Locomotive Co.,Ltd.,Zhuzhou 412001 Hunan,China)
出处 《铁道机车车辆》 北大核心 2020年第1期83-87,110,共6页 Railway Locomotive & Car
关键词 轴端接地装置 绝缘盘刚度 螺栓预紧力 强度 材料利用率 Axle end grounding device Stiffness of insulating disk Bolt preload Strength Material utilization ratio