摘要
介绍了某电站应急柴油发电机的组成和工作原理,探讨了并网带载试验结束时,发电机出口断路器失灵无法断开柴油机油门导致发电机逆功率事件的处理过程和应对措施。
The composition and working principle of the emergency diesel generator in a power plant were introduced.At the end of grid connected on load test,the handling process and countermeasures of generator reverse power event caused by the failure of generator outlet circuit breaker and failure of diesel engine throttle opening were discussed.
作者
毛雪
MAO Xue(Jiangsu Nuclear Power Co.,Ltd.,Lianyungang 222000,China)
出处
《电工技术》
2020年第1期132-133,共2页
Electric Engineering
关键词
柴油发电机
逆功率
失灵
diesel generator
reverse power
failure