期刊文献+

地铁动态直流电流干扰下管道阴极保护有效性测试技术 被引量:1

Effectiveness Test of Pipeline Cathodic Protection under Metro Dynamic DC Interference
下载PDF
导出
摘要 为了解决地铁动态直流电流干扰对埋地管道的影响问题,通过对干扰源和干扰阴极保护附属设施的调查,并对管道阴极保护有效性和检查片质量损失(或电阻探头)的测试,研究了一套阴极保护有效性测试技术。地铁动态直流干扰下阴极保护有效性测试可以很好地反映在受地铁干扰状况下管段的阴极保护状况,对管道保护具有一定的指导作用。 In order to solve the problem of metro dynamic DC interference on buried pipeline, a set of effectiveness tests for cathodic protection were summarized through investigations of interference source and related auxiliary facilities, effectiveness tests of pipeline cathodic protection and quality loss check piece(or resistance probe). The tests could properly reflect cathodic protection condition under metro interference, which had significant effect on pipeline protection.
作者 王洪志 周桐 李博 侯光祥 张琳 张家珲 WANG Hongzhi;ZHOU Tong;Li Bo;HOU Guangxiang;ZHANG Lin;ZHANG Jiahui(National Pipeline Company,Shenyang 110000,China)
出处 《石油化工腐蚀与防护》 CAS 2020年第1期42-44,共3页 Corrosion & Protection In Petrochemical Industry
基金 中油管道有限责任公司西气东输分公司“动态直流干扰下阴极保护有效性评价技术”(DBKZ1710)
关键词 动态干扰 阴极保护 测试技术 直流杂散电流干扰 dynamic interference cathodic protection testing technology DC stray current interference