摘要
介绍了唐钢美锦煤化工有限公司鼓冷初冷器的运行情况,对在运行过程中发现阻力升高的问题做了总结归纳并提出了可行的改造方案,结果表明,通过技术改造后,鼓风机以及机前整个系统运行平稳,确保了煤气正常外送。
The operation of Primary Cooler with drum cooling is introduced,This paper summarizes the problems found in the course of operation,and puts forward the feasible transformation scheme,The result shows that after the technical transformation,The blower and the whole system in front of the machine run smoothly,To make sure the gas was delivered properly。
出处
《化工设计通讯》
CAS
2020年第2期13-14,共2页
Chemical Engineering Design Communications
关键词
初冷器
阻力升高
改造
primary cooler
increased drag
remake