期刊文献+

复合肥装置皮带秤误差分析及其解决措施

Error Analysis and Solution of Belt Scale in Compound Fertilizer Plant
下载PDF
导出
摘要 通过对复合肥装置成品皮带秤结构原理、实际使用情况分析,从秤架设计安装,皮带机运行情况,以及日常使用维护等方面检查研究,找到皮带秤计量不准确的根本原因,采取针对性措施,尝试挂码和链码校验,以及原料实际投入量比对,将误差控制在0.5%左右。 Based on the analysis of the structure principle and actual use of the finished belt weigher in the compound fertilizer plant,from the aspects of the design and installation of the weigher frame,the operation of the belt conveyor,and the daily use and maintenance,the root cause of the inaccurate measurement of the belt weigher is found,and targeted measures are taken to try to hang the code and check the chain code,and the error is controlled at about 0.5% compared with the actual input of raw materials。
作者 祁维军 Qi Wei-jun
出处 《化工设计通讯》 CAS 2020年第2期89-90,共2页 Chemical Engineering Design Communications
关键词 皮带秤 链码校验 误差分析 belt scale chain code verification error analysis