期刊文献+

50000m^3常压储罐底板腐蚀检测及原因分析 被引量:2

Corrosion Detection and Analysis of 50000 m^3 Atmospheric Pressure Tank Bottom Plate
下载PDF
导出
摘要 采用漏磁检测技术对2台50000 m^3的储罐底板进行检测后发现,储罐底板多处产生了腐蚀,其中最大厚度减薄当量为60%.分析后可知,储罐原油中沉积的水分和腐蚀性介质在储罐底板上表面长期聚集导致储罐底板被腐蚀. The magnetic flux leakage testing technology was used to detect the bottom plates of two 50000 m^3 storage tanks in an enterprise.It was found that there were many corrosion places on the bottom plates of the tanks,among which the maximum thickness reduction equivalent was 60%.It could be seen from the analysis that the water and corrosive medium deposited in the crude oil of the tank accumulate on the surface of the tank floor for a long time,resulting in the corrosion of the tank floor.
作者 吴蒙蒙 张子健 张小龙 丁志千 张豪杰 胡永 WU Mengmeng;ZHANG Zijian;ZHANG Xiaolong;DING Zhiqian;ZHANG Haojie;HU Yong
出处 《化工装备技术》 CAS 2020年第1期49-51,共3页 Chemical Equipment Technology
基金 浙江省质监系统质量技术基础建设项目(20180119)。
关键词 常压储罐 漏磁检测 底板腐蚀 Atmospheric pressure tank Magnetic flux leakage testing Bottom plate corrosion