摘要
北京地铁首都机场线增购列车采用变频热泵空调系统替换既有线路的传统定频单冷空调系统,对两种方案的节能性,乘坐舒适性及可维护性进行对比分析,分析结果显示变频热泵空调在节能性、舒适性及可维护性等方面优于传统定频空调,更适用于北京首都机场线,为后续轨道列车项目空调系统方案设计提供了依据。
The frequency conversion heat pump air conditioning system is used to replace the traditional fixed frequency single cooling air conditioning system of the existing line in the additional train of Beijing Metro capital airport line.The comparative analysis of the energy saving,riding comfort and maintainability of the two schemes is carried out.The analysis results show that the frequency conversion heat pump air conditioning is superior to the traditional fixed frequency air conditioning in terms of energy saving,comfort and maintainability,which is more suitable for Beijing capital airport line It provides the basis for the air conditioning system design of the subsequent rail train project.
作者
程晓军
王绅宇
蒋政言
冯钧杰
亓海明
CHENG Xiaojun;WANG Shenyu;JIANG Zhengyan;FENG Junjie;QI Haiming(Beijing Capital Metro Co.,Ltd.,Beijing 101300,China;Shandong LONGERTEK Technology Co.,Ltd.,Qingdao 266071,China)
出处
《技术与市场》
2020年第3期5-8,共4页
Technology and Market
关键词
变频热泵空调
定频单冷空调
节能环保
舒适性
可维护性
Variable frequency air conditioning
Fixed frequency single cooling air conditioning
Energy saving and environmental protection
Comfort
Serviceability