摘要
合成气压缩机经长期停放后,透平速关阀出现了故障。通过对故障现象进行分析并对速关油路相关部件逐一检查,最终找出故障原因。采取相应的措施后,使速关阀故障得以排除。
After synthetic gas compressor has been shut down for a long time,the quick-closing valve of the turbine has failed.Through the analysis of the fault phenomenon and the inspection of related components of the quick-closing oil circuit one by one,the cause of the fault is finally found out.After corresponding measures are taken,the fault of the quick-closing valve can be eliminated.
作者
杨林
周强
朱锦燕
YANG Lin;ZHOU Qiang;ZHU Jinyan(PetroChina Ningxia Petrochemical Co.,Yinchuan,Ningxia 750026,China)
出处
《肥料与健康》
CAS
2020年第1期51-53,共3页
Fertilizer & Health
关键词
汽轮机
速关阀
故障
steam turbine
quick-closing valve