期刊文献+

ICP-MS标准加入法测定药用玻璃容器中金属元素的浸出量 被引量:6

Determination of Leaching Amount of Metal Elements in Pharmaceutical Glass Containers by ICP-MS and Standard Addition Method
下载PDF
导出
摘要 采用标准加入ICP-MS法测定药用玻璃容器在3种不同提取条件下可浸出金属元素含量,仪器工作参数:标准测定模式,同心雾化器,射频功率为1.50 kW,等离子体氩气流速为15 L·min^-1,载气流速为1.0 L·min^-1,采样深度为5.0 mm,蠕动泵速0.1 r·s^-1,雾化室温度为2℃。该方法可同时测定17种金属元素,各元素在一定的浓度范围内呈良好的线性关系,线性相关系数为0.999~1.000;加样回收率为90%~110%。经方法学验证,可用于药用玻璃容器中金属元素浸出量的测定。 ICP-MS was used for the determination of extractable components in pharmaceutical glass containers under 3 different extraction conditions.The parameters of instrument were as follows:general measurement mode,concentric nebulizer,radio-frequency(RF)power of 1.50 kW,plasma argon gas flow rate of 15 L·min^-1,carrier gas flow of 1.0 L·min^-1,sampling depth of 5.0 mm,peristaltic pump speed of 0.1 r·s^-1,atomizing chamber temperature of 2℃,quantitative analysis model and internal standard added online.The method can be used for the simultaneous determination of 17 elements,and each element had a good linear relationship within a certain concentration range.The linear correlation was 0.999~1.000,and the recoveries were 90%~110%.It is specific,sensitive,accurate and rapid,which can be used for the determination of leaching amount of metal elements in pharmaceutical glass containers.
作者 景菲 汤云 陈泱 JING Fei;TANG Yun;CHEN Yang(Jiangsu Institute of Medical Device Testing,Jiangsu Nanjing 210022,China)
出处 《广州化工》 CAS 2020年第5期107-110,共4页 GuangZhou Chemical Industry
关键词 药用玻璃容器 电感耦合等离子体质谱 多元素同时测定 标准加入 pharmaceutical glass containers inductively coupled plasma mass spectrometry(ICP-MS) simultaneous multi-element analysis standard addition
  • 相关文献

参考文献6

二级参考文献69

  • 1聂新华,阎翠环,陶金成.3种材质输液容器对药物的相容性及吸附性考察[J].中国药房,2005,16(16):1273-1275. 被引量:32
  • 2刘昌岭,贺行良.ICP—MS及其联用技术在海洋地质研究中的应用前景[J].海洋地质动态,2006,22(8):30-34. 被引量:4
  • 3何学贤,唐索寒,朱祥坤,王进辉.多接收器等离子体质谱(MC-ICPMS)高精度测定Nd同位素方法[J].地球学报,2007,28(4):405-410. 被引量:42
  • 4Hill DM,Barnes RK,Wong HK, et al .The quantification of technetium in generator - derived pertechnetate using ICP - MS[ J ]. Appl Radiat Isot, 2000,53(3) : 415.
  • 5Evans EH,Wolff JC,Eckers C.Sulfur - Specific detection of impurities in cimetidine drug substance using liquid chromatography coupled to high resolution inductively coupled plasma mass spectrometry and electrospray mass speetrometry[J] .Anal Chem, 2001,73(19):4 722.
  • 6Axelsson BO,Jornten - Karlsson M, Miehelsen P, et al.The potential of inductively coupled plasma mass spectrometry detection for high- performance liquid chromatography combined with accurate mass measurement of organic pharmaceutical compounds[J] .Rapid Commun Mass Spectrom , 2001,15(6) : 375.
  • 7Baker SA,Miller-Ihli NJ .Determination of eobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry[J ]. Spectrochi Acta Part B,2000,55(15):1 823.
  • 8Sun H,Szeto KY.Binding of bismuth to serum proteins: implication for targets of Bi( Ⅲ ) in blood plasma[J ] .J Inorg Biochem, 2003, 94( 1- 2) : 114.
  • 9Zhao Z, Tepperman K, Dorsey JG, et al .Determination of eisplatin and some possible metabolites by ion - pairing chromatography with inductively coupled plasma mass spectrometric detection[J] .J Chromatogr,1993,615(1):83.
  • 10Timerbaev AR,Aleksenko SS, Polec - Pawlak K, et al.Platinum metallodrug- protein binding studies by capillary electrophoresis - inductively coupled plasma - mass spectrometry:characterization of interactions between Pt( Ⅱ ) complexes and human serum albumln[J].Electrophoresis, 2004,25(13) : 1 988.

共引文献53

同被引文献68

引证文献6

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部