期刊文献+

ICP-AES法测定绿茶中镍含量 被引量:1

Determination of Nickel in Green Tea by ICP-AES
下载PDF
导出
摘要 为监测绿茶中污染元素镍分布范围,本文采用微波消解方法,以电感耦合等离子体发射光谱仪(ICP-AES)测定绿茶样品中镍含量。方法线性关系良好,经国家标准物质GBW10052验证,结果稳定可靠。方法检出限为9μg/L,相对标准偏差为1.6%,加标回收率为96.3%~100.6%。测定了11个绿茶样品,得到镍含量范围为1.75~16.02 mg/kg,其中有1个样品镍含量达到16.02 mg/kg,明显大于其他样品。 To monitor the content of Nickel element in green tea,eleven green tea samples were determined by inductive coupled plasma atomic emission spectrometry(ICP-AES)after microwave digestion.The method had a good linear relationship,and was in good agreement with the certified value of National Standard Reference Materials GBW10052.The limit of detection of the method was 9μg/L.The relative standard derivation was 1.6%.The recovery was in the range of 96.3%~100.6%.The content of Nickel ranged from 1.75~16.02 mg/kg,in which the highest content reached 16.02 mg/kg.
作者 王帅 邹勇平 张磊 周元元 WANG Shuai;ZOU Yong-ping;ZHANG Lei;ZHOU Yuan-yuan(Yangzhou Products Quality Supervision and Inspection Institute,Jiangsu Yangzhou 225001,China)
出处 《广州化工》 CAS 2020年第5期123-124,共2页 GuangZhou Chemical Industry
关键词 电感耦合等离子体发射光谱法(ICP-AES) 绿茶 ICP-AES green tea nickel
  • 相关文献

参考文献9

二级参考文献112

共引文献178

同被引文献19

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部