摘要 成都天府新区直管区某城市污水处理厂选用AAOA+MBR工艺进行提标改造,通过多点进水,调整回流比,改变碳源补充物质投加方式、投加量等技术改良和参数优化,使出水优质优于设计标准,为老城镇污水处理厂提标改造提供参考。 A city sewage treatment plant in the straight area of Chengdu Tianfu New District selects the AAOA+MBR process for upgrading and upgrading.Through multi-point water intake,adjusting the reflux ratio,changing the carbon source supplement material dosage method,dosage and other technical improvements and parameter optimization.To make the quality of the effluent better than the design standard,and provide reference for the upgrading of the old town sewage treatment plant.
作者 蒋悦 花春文 Jiang Yue;Hua Chunwen(College of Materials and Environmental Protection,Chengdu Textile College,Chengdu Sichuan 611731,China;Sichuan Zhongce Environmental Technology Co.,Ltd.,Chengdu Sichuan 610036,China)
出处 《环境与发展》 2020年第1期72-73,共2页 Environment & Development
关键词 AAOA+MBR 提标改造 运行效果 参数优化 AAOA+MBR Standardization transformation Operation effect Parameter optimization