期刊文献+

保国寺大雄宝殿抗震性能分析及加固对策探讨 被引量:2

Analysis on Seismic Performance of the Main Hall of Baoguo Temple and Discuss Strengthening Strategies
下载PDF
导出
摘要 通过对保国寺大殿结构振动特性现场测试,得到大殿时程分析和频谱分析,结合建筑结构、材料以及使用现状,建立有限元分析模型,并用模态分析验证该建模的真实性。结合宁波地区场地条件,通过该有限元模型在不同烈度地震作用下的反应,评定地震破坏程度。根据现场调查及模型分析结果给出保国寺大殿维护与加固建议。 By in-situ vibration characteristic testing of the main hall of Baoguo Temple,got time history analysis and spectrum analysis data,combined with architectural structure,materials and current usage,finite element analysis model is established,modal analysis is used to verify the authenticity of the model.Combined with site conditions in Ningbo,earthquake damage degree is evaluated by the response of the finite element model to earthquake with different intensity.According to the results of site investigation and model analysis,suggestions for maintenance and reinforcement of the main hall of Baoguo Temple are given.
作者 陆函 张蓓蕾 彭骁 符映红 LU Han;ZHANG Bei-lei;PENG Xiao;FU Ying-hong(Institute of Engineering Mechanics of China Earthquake Administration,Heilongjiang Harbin 150080,China;Key Laboratory of Earthquake Engineering and Engineering Vibration of China Earthquake Administration,Heilongjiang Harbin 150080,China;Ningbo earthquake Monitoring Center,Zhejiang Ningbo 315000,China;Baoguo Temple Museum of Ancient Architecture,Zhejiang Ningbo 315000,China)
出处 《防灾减灾学报》 2020年第1期6-12,共7页 Journal of Disaster Prevention And Reduction
基金 宁波市软科学项目(2017A10108) 国家重点研发计划(2018YFC1504404)。
关键词 有限元模型 模态分析 抗震 保国寺 古建筑 finite element model modal analysis anti-seismic Baoguo Temple ancient architecture
  • 相关文献

参考文献2

二级参考文献9

共引文献42

同被引文献58

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部