机械通气时的心肺交互作用及其评估手段研究进展 被引量:2

Advances in cardiopulmonary interaction during mechanical ventilation and the monitoring means
下载PDF
导出
摘要 心脏和肺同属于胸腔内脏器,不仅在解剖上相互关联,在生理功能上也存在相互作用。机械通气通过呼吸机对上气道施加正压,从而对呼吸系统及心血管系统产生不同的影响,进一步影响到血流动力学等诸多方面。评估机械通气对血流动力学等方面的影响对指导重症患者的治疗至关重要,目前常见且有效的评估手段包括动脉脉压变异度、每搏量变异度、下腔静脉呼吸变异度、上腔静脉呼吸变异度、颈内静脉呼吸变异度、呼气末屏气试验等指标。 Heart and lung are not only related in anatomy,but also interact in physiological function.Mechanical ventilation exerts positive pressure on the upper airway and causes different side effects on respiratory system,cardiovascular system and hemodynamic condition.Common assessment tools to evaluate the influence of mechanical ventilation on hemodynamics in critical patients include arterial pulse pressure variation,stroke volume variation,respiratory variation in the inferior vena cava,respiratory variation in the superior vena cava,respiratory variation in the internal jugular vein and end-expiratory occlusion test.
作者 刘妍 朱光发 Liu Yan;Zhu Guangfa(Department of Infectious Diseases,Beijing Anzhen Hospital,Capital Medical University,Beijing 100029,China)
出处 《中国医药》 2020年第3期459-462,共4页 China Medicine
基金 北京市卫生和计划生育委员会首都卫生发展科研专项(首发2016-2-1052)。
关键词 机械通气 心肺交互作用 监测手段 Mechanical ventilation Cardiopulmonary interaction Monitoring means
  • 相关文献

参考文献2

二级参考文献16

  • 1俞建峰,顾勤,刘宁.不同呼吸末正压对机械通气患者心脏前负荷影响及前负荷预测性指标研究[J].中国血液流变学杂志,2008,18(2):237-239. 被引量:12
  • 2刘松桥,邱海波,杨毅,陈永铭,李家琼,沈菊芳.每搏输出量变异度和胸腔内血容量指数对失血性休克犬容量状态的评价[J].中华外科杂志,2006,44(17):1216-1219. 被引量:27
  • 3KumarA,Anel R,Bunnell,et al.Pulmonary artery occlusion pres-sure and central venous fail to predict ventricular filling volume,cardiac performance,or the response to volume infusion in normalsubjects[J].Crit Care Med,2004,32(3):691-699.
  • 4Reuter DA,Feltinger TW,Schmidt C,et al.Stroke volume varia-tions for assessment of cardiac responsiveness to volume loading inventilated patients after cardiac surgery[J].Intensive Care Med,2002,28(4):392-398.
  • 5Zimmermann M,Feibicke T,Keyl C,et al.Accuracy of stroke vol-ume variation compared with pleth variability index to predict fluidresponsiveness in mechanically ventilated patients undergoing ma-jor surgery[J].Eur J Anaesthesiol,2010,27(6):555-561.
  • 6Mesquida J,Kim HK,Pinsky MR.Effect of tidal volume,intratho-racic pressure,and cardiac contractility on variations in pulse pres-sure,stroke volume,and intrathoracic blood volume[J].IntensiveCare Med,2011,37(10):1672-1679.
  • 7Reuter DA,Bayerlein J,Goepfert MS,et al.Influence of tidal vol-ume on left ventricular stroke volume variation measured by pulsecontour analysis in mechanically ventilated patients[J].IntensiveCare Med,2003,29(3):476-480.
  • 8Michard F.Changes in arterial pressure during mechanical ventila-tion[J].Anesthesiology,2005,103(2):419-428.
  • 9Hofer CK,Senn A,Weibel L,et al.Assessment of stroke volumevariation for prediction fluid responsiveness using the modified Flo-Trac and PiCCOplus system[J].Crit Care,2008,12(3):R82.
  • 10Michard F,Boussat S,Chemla D.Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure[J].Am J Respir Crit Care Med,2000,162(1):134-138.

共引文献7

同被引文献18

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部