660 MW发电机励端轴瓦绝缘失效故障分析与处理

Analysis and Treatment of 660MW Generator Exciter-end Bearing Insulation Failure
原文传递
导出
摘要 论述了发电机励端轴瓦绝缘失效故障的分析与处理,绝缘失效原因为绝缘套管裂纹、绝缘垫片安装或处理工艺不当、背部环氧树脂塞加工尺寸不当等8种原因,制定了应对措施,解决了发电机励端轴瓦绝缘失效故障。 It focuses on the analysis and treatment of insulation failure of generator bearing insulation.The reasons for the failure of the insulation are the crack of the insulating bushing of bolt,the improper processing or installation of the insulating gasket and the improper making of the epoxy resin plug on the back.There are eight reasons mainly lead to the poor performance of the insulating gasket.The author has formulated effective measures to solve the insulation failure.
作者 侯志华 岳兴华 范亚 熊建新 季明明 付勇 HOU Zhi-hua;YUE Xing-hua;FAn Ya(CNNC Nuclear Power Operations Management Co.Ltd)
出处 《电站系统工程》 2020年第2期34-36,共3页 Power System Engineering
关键词 发电机励端轴瓦 绝缘失效 分析 处理 generator end bearing insulation failure analysis processing