摘要
介绍了国内某电厂600 MW超超临界锅炉运行期间存在的主要问题及解决情况,针对该电厂出现的再热蒸汽温度低以及水冷壁横向裂纹等问题,进行了详细的分析,并提出了有效解决问题的方法。
The main problems and solutions during the operation of 600 MW ultra-supercritical boiler in a domestic power plant is introduced.For the low temperature of reheat steam and the lateral crack of the water wall,we have detailed analysis.And proposed a method to effectively solve the problem.
作者
商宇薇
薛长智
胡双南
高雷
龙志云
SHANG Yu-wei;XUE Chang-zhi;HU Shuang-nan(l.Harbin Boiler Co.Ltd.;Harbin Power System Engineering&Research Institute Co.,Ltd.)
出处
《电站系统工程》
2020年第2期37-38,41,共3页
Power System Engineering
关键词
600
MW超超临界
再热蒸汽温度低
水冷壁横向裂纹
分析处理
600MW ultra-supercritical
low temperature of reheat steam
lateral crack of water wall