期刊文献+

硅芯管冷弯曲半径试验器校准方法探讨及其分析与研究

下载PDF
导出
摘要 介绍了硅芯管冷弯曲半径试验器的工作原理和用途,建立了硅芯管冷弯曲半径试验器校准结果的测量模型,分析了各不确定度分量主要来源,结合测量实例具体数据,对其合成不确定度进行分析评定,对各不确定度分量进行计算并得出合成不确定度和扩展不确定度,最终可得出该项目的校准测量能力,为用于市政部门地下管道质量方面提供的技术支撑。 This paper introduces the working principle and application of high-density polyethylene silicore duct,establishes the measurement model of the calibration results of high-density polyethylene silicore duct,analyzes the main sources of each uncertainty component,analyzes and evaluates the synthetic uncertainty combined with the concrete data of the measurement example,calculates each uncertainty component,obtains the synthetic uncertainty and extended uncertainty.Finally,the calibration and measurement ability of the project can be obtained.Overall,this paper can provide strong technical support for city department underground conduit.
作者 马兴 郭贵勇
出处 《科技创新导报》 2019年第35期122-123,共2页 Science and Technology Innovation Herald
关键词 硅芯管冷弯曲半径试验器 校准方法 测量 性能影响 不确定度评定 High-density Polyethylene Silicore Duct Calibration Method Measurement Performance Impact Evaluation of Uncertainty