摘要
基于自耦变压器启动条件及启动压降允许值指标,分析了基尔霍夫定律在电动机全压启动计算中的优势。并以"雪龙2"号极地考察船为实例,验证了该方法在自耦变压器启动电压降计算和校验工程实际应用中的可行性和准确性。
Based on the starting conditions and the voltage drop allowable value for the motor starting,the advantages of the Kirchhoff law in the calculation of the starting voltage of the motor are analyzed. Taking the Snow Dragon II Polar Survey Vessel as an example,the feasibility and the accuracy of the Kirchhoff law method in calculation and verification of the motor’s voltage drop under full-voltage starting mode are presented.
作者
鲁杨
张健
林杰
宗欢
黄嵘
张懿
魏海峰
Lu Yang;Zhang Jian;Lin Jie;Zong Huan;Huang Rong;Zhang Yi;Wei Haifeng
出处
《变频器世界》
2019年第11期71-74,共4页
The World of Inverters
关键词
自耦变压器
全压起动
电压降
短路容量
Motor
Full voltage starting
Voltage drop
Short circuit capacity