期刊文献+

缩尺度试验火烟气特性实验研究

Experimental study on smoke characteristics of reduced scale test fires
下载PDF
导出
摘要 基于4种标准试验火开展缩尺度试验火烟气特性实验,研究试验火烟气特性在其尺度逐渐缩减过程中的变化规律,分析火灾烟气减光系数随时间的变化以及货架火灾探测器、吸气式感烟火灾探测器、点型感烟火灾探测器对各尺度试验火的报警响应特性。给出适用于高灵敏火灾探测器检测和评价的缩尺度试验火做法建议。 The experiments of smoke characteristics of the reduced scale test fires were carried out based on the 4 standard test fires.The change rule of smoke characteristics of test fire in the process of gradual reduction of its scale was studied and the change of the obscuration coefficient of fire smoke with time was analyzed.Alarm response characteristics of rack fire detector, inspiratory smoke fire detector and point smoke fire detector to test fire of various scales was analyzed too. Suggestions for fire test with reduced scale suitable for detection and evaluation of high sensitive fire detectors were given.
作者 李立明 宋立巍 王力 LI Li-ming;SONG Li-wei;WANG Li(Shenyang Fire Research Institute of MEM,Liaoning Shenyang 110034,China)
出处 《消防科学与技术》 CAS 北大核心 2020年第2期235-238,共4页 Fire Science and Technology
基金 辽宁省自然科学基金项目(20170520144)。
关键词 试验火 缩尺度 高灵敏火灾探测器 烟气特性 货架 test fire reduced scale high sensitivity fire detector smoke characteristics storage rack
  • 相关文献

参考文献4

二级参考文献14

  • 1孙玉平,王泓燕.物流配送中心防火设计初探[J].消防科学与技术,2004,23(6):538-540. 被引量:1
  • 2Thomas G. Cleary. Residential nuisance source characteristics for smoke alarm testing[A]. Proceedings of the 13th International Conference on Automatic Fire Detection AUBE '04[C]. Duisburg, Germany:University Duisburg-Essen. September, 2004:14 - 16.
  • 3Yan Shu, Wang Shu, Dou Zheng. An Energy Model in Fire Detection and Integrated Analysis on False Alarms.[A]. Proceedings of the 12th International Conference on Automatic Fire Detection AUBE '01 [C]. Gaithersburg, MD, USA: National Institute of Standards and Technology, March 26-28. 2001.122-128.
  • 4Xie Qiyuan, Yuan Hongyong, Guo Huiliang. Experimental Analysis on False Alarms of Fire Detectors by Cooking Fumes [J]. Journal of Fire Sciences, July, 2004. 325-338.
  • 5Mei Zhibin, Song Liwei, Li Jian, Wang Zhuofu, Li Ningning. Data Acquisition and Characteristic Analysis of the Early Fire Smoke Aerosol Information[A]. Proceedings of the 13th International Conference on Automatic Fire Detection AUBE'04 [C]. Duisburg. Germany: University Duisburg-Essen. September, 2004.14- 16.
  • 6宋立巍,梅志斌,厉剑.火灾早期多信息数据采集试验方法的研究[A].中国科协2004年年会论文集[C].北京:中国消防协会,2004.275-280.
  • 7宋立巍 卢韶然.大空间建筑火灾与典型干扰物测试试验方法的研究.电气&智能建筑,2005,:14-18.
  • 8宋波,李毅,刘欣,田立伟,杨震铭.高架仓库实体火灾的实验研究[J].消防科学与技术,2009,28(4):155-157. 被引量:23
  • 9张国欣.空气采样感烟探测报警系统在高架库中的应用[J].物流技术与应用,2013,18(2):92-94. 被引量:3
  • 10吴勤勇.浅析高架仓库火灾的早期探测报警[J].消防科学与技术,2002,21(1):56-57. 被引量:3

共引文献4