一起通信基站蓄电池组火灾事故的调查 被引量:3

Investigation of a communication base station battery fire
下载PDF
导出
摘要 介绍了金华兰溪市某通信基站的蓄电池组火灾事故,调查组通过现场勘查、物证鉴定、询问调查,并调取基站后台的电流、电压、人员进入告警、断电警报、烟雾探测器等设备运行数据,对此次起火事故进行了综合分析认定,并总结了调查此类火灾的经验。 Fire accident of a communication base station in Lanxi,Jinhua was introduced. The investigation team conducted the site investigation, material evidence identification, enquiry survey,and inquired the base station equipment operation background data such as electric current, voltage, personnel entry alarm, power failure alarm and smoke detector. The fire accident was analyzed and identified, and experience of such kinds of fire accidents were summarized.
作者 何华俊 廖定根 高怀政 HE Hua-jun;LIAO Ding-gen;GAO Huai-zheng(Jinhua Fire and Rescue Detachment,Zhejiang Jinhua 322100,China)
出处 《消防科学与技术》 CAS 北大核心 2020年第2期290-292,共3页 Fire Science and Technology
关键词 蓄电池组 电气火灾 火灾调查 battery pack electrical fire fire investigation