摘要
以地产公司设计管理者的角度,以北京某综合体项目10#地块项目车库通风和消防排烟及补风系统设计为例,从系统是否合理性、是否满足现行规范、造价、施工等方面指出了该车库设计存在的问题,并阐述了作为一个设计管理者对图纸的审核要点,针对存在的问题和审核要点进行了详细介绍并给出了优化建议方案,希冀能对车库通风和消防排烟及补风系统设计有所借鉴。
From the point of view of the design manager of the real estate company, taking the design of the ventilation, smoke control, smoke exhaust and air supply system of the garage of a 10 # block project of a complex project in Beijing as an example, this paper points out the problems existing in the garage design from the aspects of whether the system is reasonable, whether it meets the current specifications, cost and construction, and expounds the design as a design. Managers review key points of drawings, introduce the existing problems and audit key points in detail, and give optimization proposals, hoping to provide some reference for the design and design of garage ventilation, fire and smoke exhaust and air supplement system.
出处
《洁净与空调技术》
2020年第1期76-79,共4页
Contamination Control & Air-Conditioning Technology
关键词
综合体建筑
车库通风设计
车库消防排烟及补风系统设计
Complex Building
Ventilation design of garage
Design of Fire and Smoke Exhaust and Supplementary Air System in Garage