摘要
文章介绍了某电厂#5机组电除尘器在超低排放改造后出现的一起电除尘器运行故障,通过对该故障的分析,总结了在满足机组燃煤经济性及超低排放的大前提下,除尘设备安全稳定运行的经验和教训。
This paper introduces the running fault of the ESP of No.5 Unit in a power plant after the transformation for ultra-low emissions.Through the fault analysis,this paper summarizes the experience and lessons learned for safe and stable operation of the dedusting equipment under the premise of ensuring the unit's coal-burning economic advantage and ultra-low emissions.
作者
郝佳
郑立成
俞赛
HAO Jia;ZHENG Li-cheng;YU Sai(Jiangyin Ligang Power Generation Co.,Ltd,Wuxi Jiangsu 214444;Zhejiang Doway Advanced Technology Co.,Ltd,Jinhua Zhejiang 321031,China)
出处
《中国环保产业》
2020年第3期51-54,共4页
China Environmental Protection Industry
关键词
超低排放
电除尘器
MGGH
电晕闭塞
运行故障
ultra-low emissions
electrostatic precipitator
MGGH
corona quenching
running fault