针对国外炼油厂火灾报警系统设计,结合实际工程案例,从系统网络架构、报警回路设置、探测器布置和布线安装等几个方面,阐述了火灾报警系统的组成和特点,针对不同报警工况下的联动控制需求进行分析并给出了解决方案。
Aiming at fire alarm system design for abroad refinery,the composition and characteristics of fire alarm system are expounded from the aspects of network structure,alarm circuit setting,detector layout and wiring installation combined with actual engineering case.The linkage control requirements under different alarming condition are analyzed and the solution is proposed.