总结现状配电网存在的主要问题,从线路杆位路径选择、设备的合理配置、施工安装规范要求以及智能终端高度渗透等方面,对10 kV城区配电网提出优化建议,为简单、安全地开展配网不停电作业创造条件。
The main problems in the current distribution network are summarized in this paper. From aspects of the selection of line paths and line pole types,the reasonable configuration and selection of line equipment,the standardization of construction and installation,and the application of smart terminals,optimization suggestions are proposed for the 10 kV urban distribution network,in order to create conditions for simple and secure uninterrupted power distribution operations.
作者
冒波波
施昱青
朱迪
查文俊
曹勇
MAO Bo-bo;SHI Yu-qing;ZHU Di;CHA Wen-jun;CAO Yong(Shibei Power Supply Company of State Grid Shanghai Electric Power Company,Shanghai 200072,China)
出处
《通信电源技术》
2020年第5期236-237,共2页
Telecom Power Technology
关键词
配电网
不停电作业
供电可靠性
distribution network
uninterrupted operation
power supply reliability