摘要 为提高大型混凝土结构水池抗渗施工质量,对既有水池的渗漏问题进行了调研,并通过数据分析得出主要渗水部位,进而分析渗水现象产生的原因。结合具体工程,对大体积混凝土结构试验水池的抗渗措施进行了改进。渗漏检查结果显示,改进后的抗渗措施有效提高了水池的抗渗施工质量,可供类似工程参考。 To improve the anti-permeability construction quality of mass concrete structure pool, the leakage problem of existing pool is investigated, the main leakage parts are obtained through data analysis, and then the leakage causes are analyzed. Combined with an actual project, the anti-permeability measures of the test pool of mass concrete structure are improved. The results of leakage inspection show that the improved anti-permeability measures effectively improve the anti-permeability construction quality of the pool, which can be used as a reference for similar projects.
作者 杨德慧 YANG Dehui(China Shipbuilding NDRI Engineering Co.,Ltd.,Shanghai 200063,China)
出处 《建筑施工》 2020年第3期449-450,461,共3页 Building Construction
关键词 大体积混凝土结构试验水池 渗漏原因分析 止水钢板 对拉螺栓 lmass concrete structure test pool leakage cause analysis water stop steel plate split bolt