近些年我国在水处理系统方面有了较大的发展,很多半埋式超长水池结构得到了应用。但是会有很多因素影响到半埋式超长水池结构,很少采用不设缝结构,所以如何有效进行变形缝的设置就成为了此种水池的主要问题,各方也都加大了在不设缝水池结构方面的重视。本文以某水处理厂水池结构为例进行分析,通过相应措施实现了半埋式超长水池结构不设缝设计,本文所介绍的设计理念能够有效控制半埋式超长水池结构中的裂缝起到非常好的参照作用。
In recent years,China has made great progress in water treatment systems,and many semi-buried super-long pond structures have been applied.However,there are many factors that affect the structure of semi-buried super-long pools,and it is rarely used without joints.Therefore,how to effectively set the deformation joints has become the main problem of such pools.Attention is paid to the structure of the seam pool.In this paper,the structure of a water treatment plant pool is taken as an example for analysis.Through the corresponding measures,the design of the semi-buried super-long pool structure without seams is realized.The design concept introduced in this article can effectively control the cracks in the semi-buried super-long pool structure and play a very good reference role.
作者
火明譞
HUO Ming-xuan(CSCEC AECOM Consultants,Lanzhou 730000,China)
出处
《价值工程》
2020年第9期174-175,共2页
Value Engineering
关键词
半埋式水池
超长水池结构
不设缝
裂缝控制
semi-buried pool
super-long pool structure
no joints
crack control