12Mt/a常减压装置的典型腐蚀及防护 被引量:8

Typical Corrosion Cases and Protective Measures of 12Mt/a Atmospheric and Vacuum Distillation Unit
下载PDF
导出
摘要 某12Mt/a常减压装置自开工以来出现了常压塔顶低温腐蚀、减三线塔壁及集油箱腐蚀、稳定塔顶板式空冷腐蚀等,对腐蚀原因进行了分析,并提出了防护措施。塔顶低温腐蚀主要是由于盐酸和NH4Cl垢下腐蚀,应采取在脱后原油中加注2~3mg/L NaOH,将塔顶挥发线注水口改在空冷器入口分别注水,进行装置材料升级、原料控制、操作调整、腐蚀监测等防护措施。减三线及集油箱腐蚀是典型的高温硫和环烷酸腐蚀,需要采用材质升级或控制原料硫含量、酸含量等腐蚀防护措施。稳定塔顶空冷腐蚀泄漏则是由2205双相钢焊接工艺及质量问题造成的,需要控制设备制造质量及原油中的硫、氯含量。装置运行情况表明,采取的防护措施得当,腐蚀风险基本可控。 Since the start-up of a 12 Mt/a atmospheric and vacuum unit,low temperature corrosion at atmospheric overhead,reduced corrosion of the third-line tower wall and fuel tank,and stable roof-top air-cooling corrosion occurred.The causes of corrosion were analyzed and protective measures were proposed.Low temperature corrosion at the top of the tower was mainly due to hydrochloric acid corrosion and NH4 Cl under scale corrosion.The corresponding measures were as follows:2-3 mg/L NaOH was added to the crude oil after electric desalting;the water injection port of the top volatilization line was changed to water inlet at the air cooler;the protective measures such as device material upgrading,raw material control,operation adjustment and corrosion monitoring were carried out in a targeted manner.The corrosion of the third line and the fuel tank was typical high-temperature sulfur and naphthenic acid corrosion.It was necessary to use material upgrade,control of raw material sulfur content and acid content and other corrosion protection measures.The air-cooling corrosion leakage at the top of the stable tower was caused by the welding process and quality problems of 2205 duplex steel.It was necessary to control the quality of the equipment and the sulfur and chlorine content in the raw oil.The operation of the device showed that protective measures were proper and the corrosion risk was basically controllable.
作者 陈文武 郭路莉 黄贤滨 韩磊 王继虎 CHEN Wenwu;GUO Luli;HUANG Xianbin;HAN Lei;WANG Jihu(State Key Laboratory of Safety and Control for Chemicals,SINOPEC Research Institute of Safety Engineering,Qingdao 266071,China;Hebei Anke Engineering and Technology Co.,Ltd.,Shjiazhuang 050000,China;SINOPEC Qingdao Oil Refining Chemical Co.,Ltd.,Qingdao 266500,China)
出处 《腐蚀与防护》 CAS 北大核心 2020年第1期41-46,共6页 Corrosion & Protection
基金 中国石化科研项目“基于风险的炼化装置智能管控技术研究”(318021-8)。
关键词 常减压装置 盐酸腐蚀 NH4Cl垢下腐蚀 高温硫腐蚀 atmospheric-vacuum distillation unit hydrochloric acid corrosion NH4Cl under scale corrosion high temperature sulfur corrosion
  • 相关文献

参考文献4

二级参考文献28

共引文献56

同被引文献59

引证文献8

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部