期刊文献+

裂解装置冷箱冻堵和堵塞的原因分析及处理 被引量:1

CAUSE ANALYSIS AND TREATMENT ON FREEZE PLUGGING AND BLOCKAGE OF THE COLD BOX IN CRACKING UNIT
下载PDF
导出
摘要 针对中国石化齐鲁分公司烯烃厂裂解装置的特点,分析其冷箱发生冻堵和堵塞的原因。根据冷箱实际发生冻堵和堵塞的部位及特点,进行有针对性的处理和技术改进,消除了裂解装置生产运行瓶颈,降低了乙烯损失,且实现了安全生产。 Aimed at characteristics of the cracking unit in SINOPEC Qilu Branch Company,the causes for freeze plugging and blockage of the cold box were analyzed.According to the actual location and characteristics of the freeze plugging and blockage in the cold box,targeted treatment and technical improvement were executed to eliminate the production and operation bottleneck of the cracking unit;the ethylene loss was reduced,and the safe production of the unit was realized.
作者 马家胜 贾广斌 Ma Jiasheng;Jia Guangbin(Logistic Service Centre of Qilu Branch Co.,SINOPEC,Zibo Shandong 255400;The Olefins Complex of Qilu Branch Co.,SINOPEC,Zibo Shandong 255400)
出处 《齐鲁石油化工》 2020年第1期69-72,共4页 Qilu Petrochemical Technology
关键词 冷箱 冻堵 堵塞 原因分析 判断 处理 cold box freeze plugging blockage cause analysis judge treatment