期刊文献+

邓楼泵站真机能量性能现场测试与模型试验研究 被引量:2

The Field Test and Model Test to Energy Performance of Denglou Pump Station
下载PDF
导出
摘要 通过选取典型立式轴流邓楼泵站开展机组效率现场测试并结合"南水北调工程水泵模型同台测试"的试验成果,确定了泵站真机实际的能量性能指标并验证原模型能量性能结果的一致性。对今后低扬程泵站工程设计选型、原型制造安装、运行管理具有参考作用。 In this paper,a typical vertical axial-flow pump station,named Denglou,is selected to carry out the field test of unit efficiency.According to the test results of the field test and"model pump test on the same test stand as the South-to-North diversion project",the actual energy performance criterion of the pump station is determined.Meanwhile,the consistency of the prototype and model pump energy performance result is verified.Those will supply reference in the type selection and design to low-head pump station engineering,prototype manufacturing and installation,and operation management in the future.
作者 张剑雄 刘建磊 刘辉 张驰 闫宇 ZHANG Jian-xiong(Bei Fang Investigation,Design&Research Co.,Ltd,Tianjin 300222,China)
出处 《长春工程学院学报(自然科学版)》 2019年第4期67-69,共3页 Journal of Changchun Institute of Technology:Natural Sciences Edition
关键词 低扬程泵站 现场测试 模型试验 low-head pump station field test model test