摘要
通过实际检测试验的对比分析,结合实践经验,从"仪器及器具"、"试剂"、"实验用水"、"试验方法"、"环境温度"和"试验人员"5个方面对甲醛盲样测定的影响因素进行分析并提出了相应的控制方法。
After comparing and analyzing the actual detection tests, and combining with practical experience, from the" instruments and appliances", " reagents", " experimental water", " test methods", "ambient temperature" and"test personnel", the affecting factors of formaldehyde blind samples detection were analyzed, and corresponding control methods for the affecting factors were proposed.
作者
闵学武
Min Xuewu(Suzhou CITIC Energy Saving and Environmental Testing Research and Development Center Co.,Ltd.Jiangsu Suzhou 215000)
出处
《云南化工》
CAS
2020年第3期101-102,共2页
Yunnan Chemical Technology
关键词
盲样测定
甲醛检测
检测技术
Blind samples detection
Formaldehyde testing
Detecting techniques