针对20CrMnTiH圆钢在加工成齿轮过程中出现的拉键槽掉肉现象,采用直读光谱仪、金相显微镜和扫描电镜及维氏硬度计对齿轮试样进行分析。分析结果表明,齿轮拉键槽掉肉是粘刀造成的,试样加工过程中粘刀现象与试样的等温正火硬度偏低有关。
20CrMnTiH round steel appears the phenomenon of peel-off in the key during the gear forming process.The gear samples were analyzed with ARL3460 direct reading spectrometer,metallographic microscope,scanning electron microscope and Vickers hardness tester.The results show that the peel-off of the gear keyway is caused by the sticking knife in broaching.The sticking knife phenomenon in broaching sample is related to the low isothermal normalizing hardness of the sample.
作者
包锋
赵贺楠
BAO Feng;ZFAO He nan(Baowu Group Guangdong Shaoguan Iron and Steel Co., Ltd., Shaoguan,Guangdong,512123,P. R. China)