由于燃煤电厂脱硫FGD吸收塔浆液中油份会直接影响系统的整体性能,因此研究精确测试吸收塔浆液中油份的方法具有重要意义。本文通过多因素组合实验,优化了萃取方式、样品体积和萃取剂用量等因素的组合方式,确定了精确测试吸收塔浆液中油份的方法,并对样品进行了精密度和加标回收测试,研究结果表明,该方法具有良好的可行性和准确性。
It is of great significance to study the method of accurately measuring the oil content of the absorption tower,because the oil content of the desulphurization FGD absorption tower in the coal-fired power plant will directly affect the overall performance of the system.In this paper,through multi factor combination experiment,we optimized combination of extraction methods,sample volume and extraction agent Then we determined a method that can precisely test the content of oil in the absorption tower.We further carried out the precision and recovery test,which shows that this method has good feasibility and accuracy.
作者
杨小玲
吴仁军
文小于
Yang Xiaoling;Wu Renjun;Wen Xiaoyu(Hu'nan Xiangdian Test,Research Institute Co.,Ltd.,Hu'nan,410004)
出处
《当代化工研究》
2020年第7期1-3,共3页
Modern Chemical Research
关键词
脱硫
吸收塔浆液
油份
萃取
四氯乙烯
desulphurization
absorber slurry
oil content
extraction
tetrachloroethene