期刊文献+

三种消毒剂浸泡消毒对硅橡胶印模尺寸稳定性影响的研究 被引量:7

A study of silicone impression dimensional stability subjected to disinfection by three disinfectants
下载PDF
导出
摘要 目的:评价卡瓦液、优氯净、戊二醛浸泡消毒对硅橡胶印模尺寸稳定性的影响。方法:以教学用下颌标准树脂牙列模型为母模,分别用3M、GC 2种硅橡胶印模材料制取标准印模,将印模分别浸泡入3种消毒剂(实验组)和自来水(对照组)内规定时间后取出用超硬石膏灌注模型,用CT扫描三维重构技术测量设定点间的距离,组间比较,评价3种消毒剂相应时间对模型尺寸稳定性的影响。结果:3种消毒剂之间比较,实验组与对照组比较,对3M、GC 2种加成型硅橡胶印模尺寸稳定性无显著差异。结论:3种消毒剂对硅橡胶印模尺寸稳定性无影响。 Objective:To evaluate the accuracy of imprisson model disinfected respectively by 3 Cavicide,2%potentiated glutaraldehyde and 1%Sodium dichloroisocganurate.Methods:With mandibular standard model as the master pattern,3 M and GC polyvinyl siloxanes impressions were made and immersed in disinfectants(experimental groups)and tap water(control group)fetched for stipulated time,then standard casts were made with super had gypsum,the gypsum models were scanned by CT,the influence of immerse disinfection on dimensional stability was analyzed.Results:No obvious difference on dimensional stability of silicone impression was observed among all the experimental and control groups.Conclusion:The 3 disinfetants have no obvious influence on dimensional stability of silicone impression.
作者 周甜 解保生 蒋娟娜 ZHOU Tian;XIE Baosheng;JIANG Juanna(Affiliated Calmette Hospital of Kunming Medical University,650224;School of Stomatology,Kunming Medical University)
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2020年第2期295-297,共3页 Journal of Practical Stomatology
关键词 消毒剂 硅橡胶印模 螺旋CT 尺寸稳定性 Disinfectant Silicone impression Spiral CT Dimensional stability
  • 相关文献

参考文献3

二级参考文献15

  • 1Federick DR, Caputo A. Comparing the accuracy removable hydrocolloid and elastomaric impression materials. J Am Dent A ssoc, 1997, 128(2)∶183-188
  • 2Chaffee NR.Dimensional Accuracy of improved dental stone and epoxy resin die materials PartⅡ:Complete areh form. J Prosthet Dent, 1997, 77∶235-238
  • 3Gien P, MeGivey Alan B. Carr. McCracken's Removable Partial Peosthodontics, 10th Edition. Mosby Publishing Co. Inc, 2000∶221
  • 4Richards MW, Zeiaei S, Bagby MD,et al, Working times and dimensional accuracy of the one-step putty wash impression technique. J Prosthodont, 1998, 7(4)∶250-254
  • 5Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastameric impression materials. J Prosthet Dent,1990,63(1)∶12-18
  • 6Heisler WH,Tjan Anthony HL. Accuracy and bond strength of reversible with irreversible hydrocolloid impression system:A comparative study.J Prosth Dent,1992,68(4)∶578-562
  • 7Wilson HJ.Impression materials.Br Dent J,1988,164∶221-5
  • 8马轩祥主编.口腔修复学.第5版.北京:人民卫生出版社,2003∶235
  • 9Tjan AH,Nemetz H,Nguyen LT,et al.Effect of tray space on the accuracy of monophasic polyvinyl silocane impressions.J Prosthet Dent,1992,68(1):19
  • 10Gordon GE,Johnson GH,Drennon DG.The effect of tray selection on the accuracy of elastomeric impression materials.J Prosthet Dent,1990,63(1):12