期刊文献+

单颗粒冷冻电镜技术的研究现状和未来展望 被引量:2

Current Research Status and Future Prospects of Cryo-EM Technology
原文传递
导出
摘要 近年来,软件和硬件的突破性进展使得单颗粒冷冻电子显微镜技术实现了分辨率革命,成为结构生物学研究中最重要的手段之一。该技术不需要结晶,能够保证生物样品处于近生理状态下,并且所需样品量较少。在这篇文章中,我们将回顾单颗粒冷冻电镜技术的发展历程和近期的一些技术更新,并简略讨论该技术今后的发展趋势和应用前景。 Recent breakthroughs in software algorithms and hardware equipment,especially the detector technology,brought single-particle cryo-electron microscopy(cryo-EM)into the“resolution revolution”,enabling it to become one of the most popular and important tools in structural biology.This technique is capable of determining structures of macromolecules at atomic resolution without crystallization,thus maintaining these biological complexes in their close-to-native states.Herein,we review the evolution of cryo-EM in the past 40 years and recent advances,and briefly discuss its potential future perspectives.
作者 刘楠 王宏伟 Liu Nan;Wang Hongwei(Beijing Advanced Innovation Center for Structural Biology,School of Life Sciences,Tsinghua-Peking Joint Center for Life Sciences,Tsinghua University,Beijing 100084)
出处 《中国基础科学》 2019年第5期1-7,共7页 China Basic Science
基金 国家重点研发计划项目(2016YFA0501100)。
关键词 冷冻电镜 结构生物学 分辨率 生物大分子 方法学 cryo-EM structural biology resolution biological macromolecules methodology
  • 相关文献

参考文献2

二级参考文献26

  • 1Liao M, Cao E, Julius D, Cheng Y. Structure of the TRPV1 ion channel determined by electron cryo-microscopy. Nature, 2013, 504: 107-112.
  • 2Cao E, Liao M, Cheng Y, Julius D. TRPV1 structures in distinct conformations reveal activation mechanisms. Nature, 2013, 504: 113-118.
  • 3Zhang X, Settembre E, Xu C, Dormitzer PR, Bellamy R, Harrison SC, Grigorieff N. Near-atomic resolution using electron cryomicroscopy and single-particle reconstruction. Proc Natl Acad Sci USA, 2008, 105: 1867-1872.
  • 4Zhang X, Jin L, Fang Q, Hui WH, Zhou ZH. 3.3 ? cryo-EM structure of a nonenveloped virus reveals a priming mechanism for cell entry. Cell, 2010,141: 472-482.
  • 5Li X, Mooney P, Zheng S, Booth CR, Braunfeld MB, Gubbens S, Agard DA, Cheng Y. Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM. Nat Methods, 2013, 10: 584-590.
  • 6Bai XC, Fernandez IS, McMullan C, Scheres SH. Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles. Elife, 2013, 2: e00461.
  • 7Taylor KA, Glaeser RM. Retrospective on the early development of cryoelectron microscopy of macromolecules and a prospective on opportunities for the future. J Struct Biol, 2008, 163: 214-223.
  • 8Taylor KA, Glaeser RM. Electron diffraction of frozen, hydrated protein crystals. Science, 1974, 186: 1036-1037.
  • 9Adrian M, Dubochet J, Lepault J, McDowall AW. Cryo-electron microscopy of viruses. Nature, 1984, 308: 32-36.
  • 10De Rosier DJ, Klug A. Reconstruction of three dimensional structures from electron micrographs. Nature, 1968, 217: 130-134.

共引文献6

同被引文献28

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部