利用配置三阀四柱、双检测器的气相色谱仪上进行天然气组分分析,采用峰面积归一化法进行定量。该方法与原分析方法相比,不仅提高了分析数据的准确性,还把影响数据的各类因素降到最低点。
The composition of natural gas was analyzed by gas chromatograph with three valves,four columns and two detectors,and the peak area normalization method was used for quantitative analysis.Compared with the original analysis method,this method not only improves the accuracy of the analysis data,but also reduces various factors affecting the data to the lowest point.