摘要
以某330MW热电联产机组为例,对于集成吸收式热泵的热电解耦性能及能耗特性展开了理论研究。结果表明:耦合吸收式热泵扩大了热电联产机组的安全运行范围,提高了热电联产机组的最大热电比,降低了热电联产机组的最低电负荷率。当供热量为300MW时,热电联产机组电功率上调与下调能力分别增加40.53%、84.76%,最低电负荷率降低16.24%。当发电量为200MW时,其最大热电比提高了0.56。最后,对集成吸收式热泵的节能潜力进行了计算和分析。
In this study,the decoupling performance and energy consumption characteristics of the combined heat and power(CHP)plant integrated with absorption heat pump are studied with a 330MW reference CHP plant.Results show that the safe operation range of the CHP plant is expanded.The maximum heat-electric ratio is increased and the minimum electric load rate is decreased.The electricity up-regulation and down-regulation capacity are increased by 40.53%and 84.76%,respectively.The lowest electric load rate is reduced by 16.24%when the heat load is 300MW.The maximum heat-electric ratio is increased by 0.56 when the electric load is 200MW.At last,the energy saving potential of absorption heat pump is analyzed.
作者
张宇
张利
王坤
周连升
王珊
刘明
ZHANG Yu;ZHANG Li;WANG Kun;ZHOU Lian-sheng;WANG Shan;LIU Ming(State Grid Tianjin Electric Power Company Electric Power Dispatching and Control Center,Tianjin 300384,China;State Key Laboratory of Multiphase Flow in Power Engineering,Xi'an Jiaotong University,Xi'an 710049,China)
出处
《汽轮机技术》
北大核心
2020年第2期143-146,116,共5页
Turbine Technology
关键词
热电联产
吸收式热泵
解耦
节能
电热特性
heat-electricity cogeneration
absorption heat pump
decoupling
energy conservation
electro-thermal characteristics