摘要 为准确测量非标接头电缆组件电压驻波比,降低非标测试转接器对电缆组件电压驻波比的影响。对非标转接器电压驻波比进行了理论计算并对其时域进行了分析,经过实际测量和应用,确定了非标测试转接器的挑选方法。 In order to measure the voltage standing wave ratio of non-standard connector cable assembly accurately,and reduce the effect of non-standard test adapter on voltage standing wave ratio of cable assembly,I made theoretical calculation and time domain analysis of non-standard adapters,and determined the method of selecting non-standard test adapter through practical measurement and application.
作者 叶振 武向文 李闫 党程云 Ye Zhen;Wu Xiang-wen;Li Yan;Dang Cheng-yun(Xi'an TST testing technique Co.,LTD,Xi'an,Shaanxi province,China 710077;AVIC Forstar S&T Co.,LTD,Xi'an,Shaanxi province,China 710077)