期刊文献+

SARS-Cov-2实验室检测技术的应用及展望 被引量:13

Application of laboratory diagnostic technologies for SARS-CoV-2: current progress and prospect
下载PDF
导出
摘要 新型冠状病毒肺炎疫情爆发以来,我国的病毒检测能力不断提高,检测技术也在不断地发展和创新。以实时荧光定量PCR(qRT-PCR)和宏基因组测序为代表的病毒检测技术在辅助疾病确诊、监测病毒变异等方面发挥了关键作用;基于血清/血浆IgM/IgG抗体的检测技术是辅助确诊的重要方法;高特异性的逆转录环介导等温扩增技术、能够核酸定量的数字PCR和灵敏度更高的SHERLOCK技术也极具特色与发展潜力。以上检测技术代表了病原微生物检测技术的现在及未来发展方向。本文对新型冠状病毒检测技术的基本原理、技术特点及应用现状进行探讨。 Since the outbreak of COVID-19 pandemic, the detection capability has been improving and the detection techniques have been evolving with innovations. qRT-PCR and mNGS, which represent the current mainstay diagnostic technologies,play key roles in disease diagnosis and monitoring of virus variation. The detection technologies based on serum and plasma IgM and IgG antibodies are important for auxiliary diagnosis. RT-LAMP is highly specific for a diagnostic purpose. Digital PCR could quantitatively detect nucleic acid and SHERLOCK has a higher sensitivity. These techniques all have great potential for future development and application for pathogen detection. In this review the authors summarize the basic rationales,technical characteristics and the current application of the SARS-CoV-2 detection techniques.
作者 肖斌 周泉 雷婷 何咏茵 李林海 XIAO Bin;ZHOU Quan;LEI Ting;HE Yongyin;LI Linhai(Department of Laboratory Medicine,General Hospital of Southern Theatre Command of PLA,Guangzhou 510010,China)
出处 《南方医科大学学报》 CAS CSCD 北大核心 2020年第4期601-605,共5页 Journal of Southern Medical University
基金 国家自然科学基金(81802634)。
关键词 新型冠状病毒 QRT-PCR 抗体 数字PCR SHERLOCK SARS-Cov-2 qRT-PCR antibody digital PCR SHERLOCK
  • 相关文献

参考文献14

二级参考文献67

  • 1Keer J T, Birch L. Essentials of Nucleic Acid Analysis: A Robust Approach. London: Royal Society of Chemistry, 2008.
  • 2Zhang C, Xing D. Single-molecule DNA amplification and analysis using microfluidics. Chem Rev, 2010, 110(8): 4910-4947.
  • 3Vogelstein B, Kinzler K W. Digital PCR. Proc Natl Acad Sci USA, 1999, 96(16): 9236-9241.
  • 4Bhat S, Hen'mann J, Arrnishaw P, et al. Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number. Anal Bioanal Chem, 2009, 394(2): 457-467.
  • 5Bustin S A, Benes V, Garson J A, et al. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clin Chem, 2009, 55(4): 611-622.
  • 6Bums M, Burrell A, Foy C. The applicability of digital PCR for the assessment of detection limits in GMO analysis. European Food Research and Technology, 2010, 231(3): 353-362.
  • 7Sykes P J, Neoh S H, Brisco M J, et al. Quantitation of targets for PCR by use of limiting dilution. Biotechniques, 1992, 13(3): 444.
  • 8Olga K, Irina L, James B, et al. Nanoliter scale PCR with TaqMan detection. Nucleic Acids Res, 1997, 25(10): 1999-2004.
  • 9Devin D, Hai Y, Giovanni T, et al. Transforming single DNA molecules into fluorescent magnetic particles for detection and enumeration of genetic variations. Proc Natl Acad Sci USA, 2003, 100(15): 8817-8822.
  • 10Diehl F, Li M, Dressman D, et al. Detection and quantification of mutations in the plasma of patients with colorectal tumors. Proc Natl Acad Sci USA, 2005, 102(45): 16368-16373.

共引文献994

同被引文献90

引证文献13

二级引证文献33