摘要
本文对ISO 10605:2008+A1:2014《道路车辆-静电放电产生的电干扰的试验方法》与IEC 61000-4-2:2008《电磁兼容性(EMC)-第4-2部分:试验和测量技术静电放电抗扰度试验》的差异内容进行了详细解读与比较分析,提炼总结出了两个标准在仪器要求、测试环境条件、测试场地、测试布置等方面的差异,并在此基础上结合实际经验提出一种可以兼容两种测试标准的实验场地解决方案,对于实验人员执行测试以及建设同时满足两个标准测试能力的第三方试验室或研发实验室提供有益借鉴。
This paper makes a detailed interpretation and comparative analysis of the differences between ISO 10605:2008+A1:2014 test methods for road vehicle-electrical interference from electrostatic discharge and IEC 61000-4-2:2008 electromagnetic compatibility(EMC)-part 4-2:static discharge immunity test for testing and measurement techniques.The differences between the two standards in instrument requirements,test environment conditions,test sites and test layout are summarized.On this basis,combined with practical experience,a solution of experimental site that can be compatible with two testing standards is proposed.The solution will provide a useful reference for the experimenters to perform tests and building a third party laboratory or r&d laboratory that can meet both standard test capabilities.
作者
陈传好
吴志平
CHEN Chuan-hao;WU Zhi-Ping(China Electric Appliance Research Institute Co.,Ltd.,Guangzhou 510850)
出处
《环境技术》
2020年第2期214-218,222,共6页
Environmental Technology
关键词
静电放电
放电模块
测试条件
测试场地
electrostatic discharge
discharge module
test conditions
test site